This adapter enables 110v portable electrical appliances to be tested using the PB500 Easy PAT tester for earth bond and insulation resistance. Simply place the 240v plug into the front of the PB500 and the yellow adaptor end into the 110v lead of the appliance to be tested. Press the relevant button and it will perform the tests.

Came really quickly very pleased

Earth Continuity

Pass Limit

0.2 Ohms

Accuracy

+/- 0.03 Ohms

Test Current

200mA minimum

Test Voltage

9V nominal


Insulation Resistance

Pass Limit

1.0M Ohms CL I

2.0M Ohms CL II

2.0M Ohms Mains Cord

Accuracy

+/- 0.1M Ohms

Test Voltage

Test Current

>1mA into 500k Ohms

Test Current

<2mA into 2k Ohms

Cord Test

Earth continuity, insulation resistance as above. Check for Live and Neutral open circuit, short circuit or reversed polarity.

Environmental Rating

IP40
Operating Temperature Range 0°C to 40°, without moisture condensation.
Storage Temperature Range -25° to 65° Batteries should be removed prior to storage.
Overvoltage Category 300V CAT II 

The IET Code of Practice for In-service Inspections and Testing of Electrical Equipment (4th Edition) states that "The accuracy of a test instrument be verified annually or in accrodance with the manufacturer's instructions." 

"Such machine testing should be carried out by a formal calibration house, and the testing of the test leads should be assessed at the time of calibration."