Call us on: 01392 308110

PAT Tester - 110v Extension Lead Adapter

110v Extension Lead Adapter P026


 

£17.95

(£21.54 inc tax)
In stock
+

This adapter tests 110v extension leads when used in conjunction with the PB500 Easy PAT tester and the 110v adapter.

No posts found

Earth Continuity

Pass Limit

0.2 Ohms

Accuracy

+/- 0.03 Ohms

Test Current

200mA minimum

Test Voltage

9V nominal


Insulation Resistance

Pass Limit

1.0M Ohms CL I

2.0M Ohms CL II

2.0M Ohms Mains Cord

Accuracy

+/- 0.1M Ohms

Test Voltage

Test Current

>1mA into 500k Ohms

Test Current

<2mA into 2k Ohms

Cord Test

Earth continuity, insulation resistance as above. Check for Live and Neutral open circuit, short circuit or reversed polarity.

Environmental Rating

IP40
Operating Temperature Range 0°C to 40°, without moisture condensation.
Storage Temperature Range -25° to 65° Batteries should be removed prior to storage.
Overvoltage Category 300V CAT II 

The IET Code of Practice for In-service Inspections and Testing of Electrical Equipment (4th Edition) states that "The accuracy of a test instrument be verified annually or in accrodance with the manufacturer's instructions." 

"Such machine testing should be carried out by a formal calibration house, and the testing of the test leads should be assessed at the time of calibration."